French industrial expertise · Since 1994
DAS
Industrial dust collector
A dust collector for intermittent production cycles, with motorised filter cleaning when stopped at the end of each cycle.
Technical data sheet available in French.
01 / The right application
Daily intermittent use
The DAS range suits daily intermittent use. Filter cleaning relies on vibration generated by an eccentric driven by a secondary motor. Cleaning takes place while stopped, at the end of the cycle. Five models cover low and medium pressure configurations.
Request a quote02 / How it works
DAS
- The motor and fan assembly creates negative pressure. Dust laden air enters the settling chamber.
- Coarse dust falls by gravity into the bucket or drawer; fine particles are retained on the filter element.
- At the end of the cycle, with the fan stopped, the secondary motor drives the eccentric to vibrate and clean the filters.

03 / Technical specifications
Technical specifications
| Model | Airflow m³/h · BP / MP |
Pressure mm WC · BP / MP | Power kW · BP / MP |
|---|---|---|---|
| 120 | 800 / 400 | 70 / 160 | 0.37 / 0.75 |
| 150 | 1 200 / 600 | 100 / 175 | 0.75 / 0.75 |
| 200 | 2 400 / 1 500 | 125 / 260 | 1.5 / 2.2 |
| 250 | 4 000 / 2 500 | 140 / 300 | 3 / 4 |
| 400 | 5 000 / 3 000 | 130 / 300 | 5.5 / 4 |
BP: low pressure · MP: medium pressure. Values from the technical data sheets. General range summaries may differ from individual model values; the table details the listed configurations. Final selection depends on the operating point.
2 mm electrogalvanised steel with epoxy powder coating. 400 V supply. Spare parts available for 10 years.
04 / Options and variants
Options and variants
Options are selected according to the pollutant, ductwork and operating conditions.
304 / 316 L stainless steel variants and different orientations to suit the layout.
PTFE or antistatic filter media depending on configuration.
ATEX variant available subject to configuration and risk assessment.
Your industrial project
Select the right equipment.
Tell us about the pollutant, the required airflow and your production schedule. Our team will help you select the model and its options.

Bag-type DA
DA
DAS CC
HYDRO