French industrial expertise · Since 1994

DAS CC
Industrial dust collector

A cartridge range for continuous processes, with reverse pulse compressed air cleaning controlled by an electronic sequencer.

Technical data sheet available in French.

600 – 19 200m³/h
7models
24/7continuous operation

01 / The right application

Continuous production 24/7

The DAS CC is intended for processes running continuously, 24 hours a day, seven days a week. Pneumatic cleaning keeps the cartridges in service during operation, without manual intervention for this task. Seven models range from DAS CC 150 to DAS CC 1000, listed at up to 19,200 m³/h.

Request a quote
01Continuous processes 24/7
02Pneumatic filter cleaning
03Electronic sequencer

02 / How it works

DAS CC

  1. The motor and fan assembly creates negative pressure and draws dust laden air through the filter elements.
  2. The electronic sequencer controls reverse pulses of compressed air to clean the cartridges during operation.
  3. Cartridges are serviced through the front door, with screw fastened access. Pneumatic cleaning requires a compressed air supply.
Industrial dust collector CAPTAIR DAS CC

03 / Technical specifications

Technical specifications

DAS CC — Technical specifications
ModelAirflow
m³/h · BP / MP
Pressure
mm WC · BP / MP
Power
kW · BP / MP
1501 200 / 600100 / 1750.75 / 0.75
2002 400 / 1 500125 / 2601.5 / 2.2
2504 000 / 2 500140 / 3003 / 4
4005 000 / 3 000130 / 3005.5 / 4
5007 000 / 4 000145 / 3505.5 / 7.5
80011 000 / 8 000120 / 32011 / 15
1000Up to 19 200Subject to engineering assessmentSubject to engineering assessment

BP: low pressure · MP: medium pressure. Values from the technical data sheets. General range summaries may differ from individual model values; the table details the listed configurations. Final selection depends on the operating point.

2 mm electrogalvanised steel with epoxy powder coating. 400 V supply. Spare parts available for 10 years.

04 / Options and variants

Options and variants

Options are selected according to the pollutant, ductwork and operating conditions.

  • H13 filtration housing
  • Outlet monitoring probe
  • Filter clogging indicator
  • Acoustic attenuator
  • Bagging system

304 / 316 L stainless steel variants and different orientations to suit the layout.

PTFE or antistatic filter media depending on configuration.

ATEX variant available subject to configuration and risk assessment.

Your industrial project

Select the right equipment.

Tell us about the pollutant, the required airflow and your production schedule. Our team will help you select the model and its options.